Description
A brass ball valve with BSP flare (30°) and loose nut & tail connections AGA approved to AS 4617 (Licence 5301 G). The loose nut and integral tail reduce the number of joints required to safely connect copper gas pipe to a continuous flow water heater while a quality PTFE washer offers additional leak protection by sealing between the valve and appliance.
Design
Forged nickel-plated brass body & nuts
PTFE washer for reliable leak-free sealing against an appliance
Blow-out proof stem to prevent leakage
Production
Manufactured in Italy under ISO 9001 Quality Management System
All valves are pressure tested during production
Technical
JIS-30° flare connection conforming to AS 3688
Loose nut: ISO 228/1 (BSPF) female parallel threaded connection
Flow control: on/off only, not intended for throttling
Flow capacity: Full bore
Temperature range: -10°C to 80°C
Max. pressure: 2100 kPa *
*According to AS 5601 Table 4.1, the operating pressure of consumer gas piping systems containing copper is 200 kPa